1728EX v.2.4 1738 v.2.1 instal.pdf
(
1801 KB
)
Pobierz
1728EX / 1738/ 1738U2 : Reference & Installation Manual
R
EFERENCE
& I
NSTALLATION
M
ANUAL
S
PECTRA
C
ONTROL
P
ANELS
1728EX: V2.4
1738/1738U2: V2.1
1728EX
1738/1738U2
TABLE OF CONTENTS
Introduction ....................................................... 3
Features ............................................................................... 3
Specifications ....................................................................... 3
Bell Squawk On Arm/disarm with Remote Control ............. 25
No Exit Delay When Arming with Remote Control .............. 25
No Exit Delay Beeps and No Bell Squawk When
Stay Arming ........................................................................ 25
Installation......................................................... 4
Location and Mounting ......................................................... 4
Earth Ground ........................................................................ 5
AC Power ............................................................................. 6
Backup Battery ..................................................................... 6
Auxiliary Power Terminals .................................................... 6
Telephone Line Connection.................................................. 6
Bell Output Connection......................................................... 7
Programmable Output Connections ..................................... 7
Single Zone Inputs ............................................................... 8
Double Zone Inputs (with ATZ Option only) ......................... 8
Keypad and Keypad Zone Connections ............................... 9
Keyswitch Connections ........................................................ 9
Fire Circuits .......................................................................... 9
Alarm Options ................................................. 25
Bell Cut-Off Timer .............................................................. 25
Recycle Alarm ..................................................................... 26
Tamper Recognition............................................................ 26
Keypad Panic Options ........................................................ 26
Panic Lockout Timer ........................................................... 27
Reporting and Dialer settings ......................... 27
Reporting/Dialer ................................................................. 28
Report Codes...................................................................... 29
Central Station Telephone Numbers................................... 31
Partition Account Numbers ................................................. 32
Reporting Formats .............................................................. 32
Pager Format Transmission Options ................................. 33
Pager Delay ........................................................................ 33
Event Call Direction ............................................................ 33
Dialing Method .................................................................... 34
Pulse Ratio.......................................................................... 34
Bell on Communication Failure ........................................... 34
Dial Tone Delay .................................................................. 34
Maximum Dialing Attempts ................................................. 34
Delay Between Dialing Attempts......................................... 35
Alternate Dial Option........................................................... 35
Recent Close Delay ............................................................ 35
Auto Test Report................................................................. 35
Closing Delinquency Timer ................................................ 35
Power Failure Report Delay................................................ 35
Disarm Reporting Options................................................... 36
Zone Restore Report Options ............................................. 36
Telephone Line Monitoring (TLM) ....................................... 36
Programming Methods..................................... 10
WinLoad Software for Windows ......................................... 10
Programming Using a Keypad............................................ 10
Configuring the LED Keypads ............................................ 11
Programming Using A Paradox Memory Key..................... 12
Access Codes .................................................. 13
Access Code Length .......................................................... 13
Installer Code ..................................................................... 13
System Master Code ......................................................... 13
User Code Options ............................................................. 14
Lock Master Code .............................................................. 15
Duress Code....................................................................... 15
Zone Programming .......................................... 15
What is an Expansion Input?.............................................. 16
Reassign Keypad Zone 2 ................................................... 16
Reassign Zones to Expansion Inputs ................................ 16
Zone Programming............................................................. 17
Zone Definitions.................................................................. 17
Exclusive Zone Definitions ................................................. 18
Zone Partition Assignment ................................................. 19
Zone Options ...................................................................... 20
Zone Speed ........................................................................ 21
EOL Zones ......................................................................... 22
ATZ - Zone Doubling ......................................................... 22
2-Wire Smoke Detector Support ........................................ 22
Programmable Outputs .................................. 37
PGM Activation Event ......................................................... 37
PGM Deactivation Event ..................................................... 37
PGM Delay.......................................................................... 37
PGM Normal State.............................................................. 38
PGM2 Strobe Options ......................................................... 38
Alarm Relay Options .......................................................... 38
System Settings .............................................. 38
Hardware Reset .................................................................. 38
Installer Lock....................................................................... 38
Keypad Lockout Feature..................................................... 39
Battery Charge Current ...................................................... 39
Partitioning .......................................................................... 39
System Real-Time Clock .................................................... 39
Clock Adjust ........................................................................ 39
Keypad Tamper Supervision............................................... 40
Keypad Audible Trouble Warning ....................................... 40
Confidential Mode ............................................................... 40
Installer Quick Functions Keys............................................ 41
4-Output Bus Module* Supervision ..................................... 41
Printer Bus Module Supervision.......................................... 41
Zone Expansion Bus Module* Supervision ......................... 42
Wireless Bus Module Supervision ...................................... 42
Arming and Disarming Options........................ 23
Switch To Stay Arming ....................................................... 23
Stay Arming with Delay ...................................................... 23
Regular Arming switches to Force Arming ......................... 23
Restrict Arming On Battery Fail .......................................... 23
Restrict Arming On Tamper Failure.................................... 23
Timed Auto-Arming............................................................. 23
No Movement Auto-Arming ................................................ 24
Auto-Arming Options .......................................................... 24
One-Touch Arming ............................................................. 24
Exit Delay ........................................................................... 25
Bell Squawk On Arm/Disarm With Keypad......................... 25
S
PECTRA
S
ERIES
1
Wireless Transmitter Low Battery Supervision ................... 42
Wireless Transmitter Supervision Options.......................... 42
ReProgram All Expansion Modules .................................... 43
Settings for WinLoad Software....................... 43
Panel Answer Options ........................................................ 43
Panel Identifier .................................................................... 44
PC Password ...................................................................... 44
PC Telephone Number ....................................................... 44
Call WinLoad Software ....................................................... 44
Answer WinLoad Software.................................................. 44
Auto Event Buffer Transmission ......................................... 44
Call Back WinLoad.............................................................. 45
User Operation ............................................... 45
Trouble Display ................................................................... 45
Programming Access Codes .............................................. 46
Disarming & Deactivating an Alarm .................................... 47
Regular Arming ................................................................... 47
Stay Arming ........................................................................ 47
Instant Arming..................................................................... 48
Force Arming ...................................................................... 48
Manual Bypass Programming............................................. 48
One-Touch Arming.............................................................. 49
Keyswitch Arming ............................................................... 49
Panic Alarms....................................................................... 50
Auto-Arming ........................................................................ 50
Alarm Memory Display........................................................ 50
Programming Chime Zones ................................................ 50
Keypad Muting .................................................................... 50
Keypad Backlight ............................................................... 50
FCC WARNINGS .............................................. 51
Index................................................................ 54
L
IST
OF
T
ABLES
Transformer Requirements Table ......................................... 6
Current Consumption Table .................................................. 6
Decimal and Hexadecimal Programming Table .................. 10
Zone Recognition Table ...................................................... 15
Zone Display with 10-Zone LED Keypad ............................ 16
Reporting Formats .............................................................. 32
Special Keys for Telephone Numbers ................................ 32
Zone Tamper Report Code for Keypad Tamper
Supervision Failure ............................................................. 40
Trouble List ......................................................................... 45
2
R
EFERENCE
& I
NSTALLATION
M
ANUAL
PART 1: INTRODUCTION
1.1 FEATURES
• Up to 16 fully programmable zones
• Two completely independent partitions. Many of the features and options in the Spectra System can be independently
set for each partition such as event reporting, entry/exit delay, auto-arming and many more. All zones, the keyswitches
and all user codes are assigned to specific partitions, which makes this a true partitioned system.
• Communication bus facilitates the adding, programming and monitoring of all expansion modules.
• 1 Installer Code and 48 User Codes (including: 1 System Master, 2 Masters, and 1 Duress)
• 1738: 2 on-board, fully programmable outputs (PGMs) and 1 optional 5A alarm relay
• 1728EX/1738U2: 2 on-board, fully programmable outputs
• Simple, direct and logical programming
• Event Call Direction: The Spectra Series Control Panel events are divided into 5 groups of events. Each of these event
groups can be programmed with a separate dialing sequence.
• Two 32-digit Central Station Telephone Numbers and one 32-digit Backup Telephone Number
• Contact ID, Pager Format and many more High-Speed Communication Formats
• "False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable Delay
Before Alarm Transmission, and Recent Closing Report
• Regular Arming, Stay Arming, Instant Arming, Force Arming, One-Touch Arming, Auto-Arming, or Keyswitch Arming
• 256 Event Buffer with time stamp
• Telephone Line Supervision
• Keypad activated panic alarms
• Compatible with Winload Security System Management Software for Windows®
1.2 SPECIFICATIONS
1.2.1 S
PECTRA
C
ONTROL
P
ANELS
• C wr:
*
16VAC transformer with minimum 20VA rating (Rec.: 40VA), 50 to 60Hz
• Battery:
12VDC, 4Ah/7Ah
• . r:
+
600mA typical, 700mA maximum, fuseless shutdown @ 1.1A
• Bell Output:
++
1A, fuseless shutdown @ 3A
• PGM Outputs:
1728EX: PGM1 and PGM2 = 150mA
1738/1738U2: PGM1 and PGM2 = 1A
• Alarm Relay:
One form “C” relay rated @ 125V, 5A receptive load (1738 only)
1.2.2 S
PECTRA
K
EYPADS
(1686H, 1686V, 1689 & 1641)
• Power input:
9-16VDC,
• 1 standard keypad zone
• On-board Tamper Switch (optional)
1686H & 1686V 10-Zone LED Keypad
• Current Consumption:
62 to 116mA
1689 16-Zone LED Keypad
• Current Consumption:
50 to 117mA
1641 32-Character LCD Keypad
• Current Consumption:
60 to 80mA
• PGM:
1 with 50mA current limit
• LCD:
Super Twisted Nematic display (STN), Wide viewing angle, Backlight &
Contrast adjustable
* Only the 16.5VAC, 40VA version is UL listed.
+
200mA typical for UL installations
++
1A for UL installations total, including PGM options
S
PECTRA
S
ERIES
3
Plik z chomika:
jimasek
Inne pliki z tego folderu:
versa_p_pl_0309.pdf
(745 KB)
versa_iu_pl_0309.pdf
(631 KB)
versa_ii_pl_0309.pdf
(623 KB)
vd1_io_pl_0908.pdf
(119 KB)
t_indigo_pl.pdf
(164 KB)
Inne foldery tego chomika:
Adresy
Axis
DSC
Elmes
Esser
Zgłoś jeśli
naruszono regulamin