1
TURNIGY ACCUCELL-6
BALANCE CHARGER/DISCHARGER
FOR NICD/NIMH/LITHIUM/PB BATTERIES
Operating Manual
Thank you for purchasing the TURNIGY. This is a rapid
charge/discharger with built in balancer, computerised with micr-
oprocessor and specialised operating software. Please read this
entire operating manual completely and attentively before using.
.
94041666.017.png
Features
Optimised operating software
When charging or discharging, it has an ‘AUTO’ function that sets the
feeding current automatically. Especially for Lithium batteries, it can prevent
the over-charging can lead to an explosion by users fault. Every program in
the unit is controlled with mutual links and communication for every possible
error so it introduces a maximum safety. These can be set at users option.
Special recharge plugsport for receiver,transmitter and igniter charger. And
for frequently used charger port such as multi purpose crocodile pin etc.
It provides most convenient balance charge port for Lithium batteries, with
separated 3,4,5,6 charge port, and external reverse connector.
High-power and high-performance circuit
It employs the circuit that has maximum output power of 50W. As a result it
can charge or discharge up to 15cells of NiCd/NiMH and 6 series of Lithium
batteries with maximum current of 5.0A. Furthermore the cooling system is
so efficient that can hold such a power without any trouble of running the
CPU or the operating program.
Individual voltage balancer for Lithium batteries insideh
It has an individual-cell-voltage balancer inside.This does not require any
extra balancer separately when charging Lithium batteries(Lilo/LiPO/LiFe)
for cell voltage balancing.
Balance individual cells on discharge
It also can monitor and balance individual cells of the Lithium battery pack
during the discharge process. If the voltage of any one cell varies abnormally,
the process will be stopped with the error message.
Accept various types of Lithium battery
It can accept three types of Lithium batterles- Lilo, LiPo and LiFe. They have
different characteristics by their chemistry. You can select any one of them
that you are going to process before the job. For their specifications,
refer‘Warnings and safety notes’section.
Lithium battery ‘Fast’and ‘Storage’mode
You can charge Lithium battery for special purposes. ‘Fast’charge reduces
the charging time of Lithium battery and ‘Storage’mode controls the final
voltage of the battery to be suit for long time storage.
Maximum safety
Delta-peak sensitivity: The automatic charge termination program works on
the principle of the Delta-peak voltage detection.(NiCd/NiMH)
94041666.018.png
Auto-charge current limit: When charging NiCd or NiMH at
‘AUTO’current mode, you can set the upper limit of change current
to avoid from high current charging. This is very useful when charg-
ing the low impedance and small capacity NiMH battery in
“AUTO’mode.
Capacity limit: The changing capacity always calculated by
multiple of the charging current and time. If the charging capacity
exceeds the limit the process will be terminated automatically when
you set the maximum value.
Temperature limit(*): The temperature of the battery on charging will
rise by its internal chemical reaction. If you set the limit of tempera-
ture the process will be expired forcibly when the limit has reached.
Processing time limit: you can also restrain the maximum process
time to prevent from any possible defect.
Input power monitor: To protect the car battery using as input power
from being damaged the voltage of it always monitored. If it dorps
below the lower limit the process will be ended automatically.
Automatic cooling fan: The electric cooling fan comes into action
automatically only when the internal temperature of the unit is
raised.
Data store/load
For users convenience it can store maximum 5 data of different
batteries. You can establish the data contains program setting of the
battery to charge or discharge continually. These data can be called
out at any time you need and the process can be executed without
program setting.
Cyclic charging/discharging
Perform 1 to 5 cycles of charge>discharge or discharge>charge
continually for battery refreshing and balancing.
Exterior of the unit
Lithium balance charge program connection diagram
WARNING
It will damage the charger if you connect your battery with the TURNIGY-
charger incorrectly. Please connect as shown in the following diagram
carefully.
94041666.019.png 94041666.020.png 94041666.001.png 94041666.002.png 94041666.003.png 94041666.004.png 94041666.005.png 94041666.006.png 94041666.007.png 94041666.008.png 94041666.009.png 94041666.010.png 94041666.011.png 94041666.012.png 94041666.013.png 94041666.014.png 94041666.015.png
 
Warnings and safety notes
�Never leave the charge unsupervised when it is connected to its power
supply. If any malfunction is observed immediately terminate the process and
refer to the operation manual.
�Keep away the unit from dust, damp, rain, heat direct sunshine and
vibration. Do not dorp it.
�The circuit of the unit is designed to be powered by a 10-18V DC only.
�This unit and the battery to charge or discharge should be set up on a
head-resistant, non-inflammable and non-conductive surface. Never place
them on a car seat, carpet or similar. Keep all the inflammable volatile materi-
als well away from operating area.
�Be sure to understand the information of the battery to be charged or
discharged accurately. If the program is set up incorrectly the battery can
severely be damaged. Especially Lithium battery can cause a fire or an
explosion by over-charging.
NiCd/NiMH voltage level:1.2V/cell
allowable fast charge current:1C~2C depends on the
performance of cell discharge voltage cut off level
0.85V/cell(NiCd), 1.0V/cell(NiMH)
Lilo voltage level:3.6V/cell
max.charge voltage:4.1V/cell
allowable fast charge current: 1C or less
min.discharge voltage cut off level:2.5V/cell or higher
LiPo voltage level:3.7V/cell
max.charge voltage:4.2V/cell
allowable fast charge current: 1C or less
discharge voltage cut off level:3.0V/cell or higher
Life voltage level:3.3V/cell
max.charge voltage:3.6V/cell
allowable fast charge current: 4C or less(e.g. A123M1)
discharge voltage cut off level:2.0V/cell or higher
Pb voltage level:2.0V/cell
(Lead-acid) max.charge voltage:2.46V/cell
allowable fast charge current:0.4C or less
discharge voltage cut off level:1.50V/cell or higher
�To avoid short-circuits between the charge lead, always connect the charge
cable to the unit first and only then to the battery to be charged or discharged.
Reverse the hsequence when disconnecting.
94041666.016.png