This RTB has been issued to announce the firmware release information for the Engine (BICU-IC).

 

For USA/Europe basic model

 

Version

Program No.

Effective Date

0.32

B2625531F

Sep/07 production

0.31

B2625531E

Feb/07 Production

0.27

B2625531C

August 2006 production

0.26

B2625531B

1st Mass production.

 

Version

Modified Points or Symptom Corrected

0.32

Basic Model only:

1.      If a DF jam occurs when the counting timing for the optional key card is set to "At paper exit", the blank page that is printed out is then counted.

2.      An OHP sheet fed from the bypass tray is counted as thick paper when printing from the GDI controller.

Basic and MFP model:

3.      White spots appear on the image.

0.31

1.      One page was not counted on the key counter when in odd pages duplex printing.

2.      Duplex printing was not control properly when the decrement key card was connected on the machine.

3.      Word data correction for the multiple languages.

0.27

Symptom corrected:

The machine stops scanning the original under the following conditions:

  - The originals are scanned in the DF using reduction

  - Many originals are scanned in simplex mode

 

Other changes:

Changed the registration adjustment range for the DF main-scan

0.26

For 1st Mass production.

 

 

 

 

For Asia basic model

 

Version

Program No.

Effective Date

0.32

B2625533C

Sep/07 production

0.31

B2625533B

Feb/07 Production

0.26

B2625533A

1st Mass production.

 

Version

Modified Points or Symptom Corrected

0.32

Basic Model only:

1.      If a DF jam occurs when the counting timing for the optional key card is set to "At paper exit", the blank page that is printed out is then counted.

2.      An OHP sheet fed from the bypass tray is counted as thick paper when printing from the GDI controller.

Basic and MFP model:

3.      White spots appear on the image.

0.31

1.      One page was not counted on the key counter when in odd pages duplex printing.

2.      Duplex printing was not control properly when the decrement key card was connected on the machine.

3.      Word data correction for the multiple languages.

0.26

For 1st Mass production.

 

For Generic MFP model

 

Version

Program No.

Effective Date

0.28

B2625540E

Mar/08 production

0.27

B2625540D

Sep/07 Production

...