EASY204-DP PROFIBUS-DP Slave Interface
User Manual
09/10 MN05013005Z-EN
replaces 03/05 AWB2528-1401GB
EASY204-DP
PROFIBUS-DP Slave Interface
 
440896737.006.png 440896737.007.png
 
440896737.001.png
 
 
 
All brand and product names are trademarks or registered
trademarks of the owner concerned.
Emergency On Call Service
Please call your local representative:
http://www.eaton.com/moeller/aftersales
or
Hotline After Sales Service:
+49 (0) 180 5 223822 (de, en)
AfterSalesEGBonn@eaton.com
Original Operating Instructions
The German-language edition of this document is the
original operating manual.
Translation of the original operating manual
All editions of this document other than those in German
language are translations of the original German manual.
1 st published 2001, edition date 04/01
2 nd edition 2002, edition date 08/02
3 rd edition 2003, edition date 05/03
4 th edition 2004, edition date 07/04
5 th edition 2005, edition date 03/05
6 th edition 2008, edition date 02/08
7 th edition 2010, edition date 09/10
See revision protocol in the “About this manual“ chapter
© 2001 by Eaton Industries GmbH, 53105 Bonn
Production: Thomas Kracht, Barbara Petrick
Translation: Terence Osborn
All rights reserved, including those of the translation.
No part of this manual may be reproduced in any form
(printed, photocopy, microfilm or any other process) or
processed, duplicated or distributed by means of electronic
systems without written permission of Eaton Industries
GmbH, Bonn.
Subject to alteration without notice
440896737.002.png
Danger!
Dangerous electrical voltage!
Before commencing the installation
• Disconnect the power supply of the device.
Ensure that devices cannot be accidentally
restarted.
Verify isolation from the supply.
Earth and short circuit.
Cover or enclose neighbouring units that
are live.
Follow the engineering instructions (AWA)
of the device concerned.
Only suitably qualified personnel in
accordance with EN 50110-1/-2
(VDE 0105 Part 100) may work on this
device/system.
Before installation and before touching
the device ensure that you are free of
electrostatic charge.
The functional earth (FE) must be
connected to the protective earth (PE) or
to the potential equalisation. The system
installer is responsible for implementing
this connection.
Connecting cables and signal lines should
be installed so that inductive or capacitive
interference does not impair the
automation functions.
Install automation devices and related
operating elements in such a way that they
are well protected against unintentional
operation.
Suitable safety hardware and software
measures should be implemented for the
I/O interface so that a line or wire breakage
on the signal side does not result in
undefined states in the automation
devices.
Ensure a reliable electrical isolation of the
low voltage for the 24 volt supply. Only
use power supply units complying with
IEC 60364-4-41 (VDE 0100 Part 410) or
HD 384.4.41 S2.
Deviations of the mains voltage from the
rated value must not exceed the tolerance
limits given in the specifications, otherwise
this may cause malfunction and dangerous
operation.
Emergency stop devices complying with
IEC/EN 60204-1 must be effective in all
operating modes of the automation
devices. Unlatching the emergency-stop
devices must not cause restart.
Devices that are designed for mounting in
housings or control cabinets must only be
operated and controlled after they have
been installed with the housing closed.
Desktop or portable units must only be
operated and controlled in enclosed
housings.
I
440896737.003.png 440896737.004.png
 
Measures should be taken to ensure the
proper restart of programs interrupted
after a voltage dip or failure. This should
not cause dangerous operating states even
for a short time. If necessary, emergency-
stop devices should be implemented.
Wherever faults in the automation system
may cause damage to persons or property,
external measures must be implemented to
ensure a safe operating state in the event
of a fault or malfunction (for example, by
means of separate limit switches,
mechanical interlocks etc.).
II
09/10 MN05013005Z-EN
Contents
About This Manual
11
List of revisions
11
Target group
11
Other manuals on the device
12
Device designation
12
Abbreviations
13
Writing conventions
14
1 EASY204-DP
15
System overview
16
Structure of the unit
17
Device function description
18
– easy600/700/800, MFD-CP8…
18
– easy800/MFD-CP8…
19
Hardware and operating system preconditions
19
List of modifications
20
Improper use
20
2 Installation 21
Connecting EASY204-DP to the basic unit 21
Connecting the power supply 22
Connect PROFIBUS-DP 23
Connection assignment PROFIBUS-DP 23
Terminal resistors 24
EMC-conformant wiring of the network 24
Potential isolation 25
Data transfer rates – automatic baud rate detection 26
Maximum distances/bus cable lengths
26
1