BTA40 and BTA/BTB41 Series
[
40A TRIAC S
STANDARD
MAIN FEATURES:
A2
Symbol
Value
Unit
I T(RMS)
40
A
G
A1
V DRM /V RRM
600 and 800
V
A1
A2
I GT (Q 1 )
G
50
mA
DESCRIPTION
Available in high power packages, the BTA/
BTB40-41 series is suitable for general purpose
AC power switching. They can be used as an ON/
OFF function in applications such as static relays,
heating regulation, water heaters, induction motor
starting circuits, welding equipment... or for phase
control operation in high power motor speed con-
trollers, soft start circuits...
Thanks to their clip assembly technique, they
provide a superior performance in surge current
handling capabilities.
By using an internal ceramic pad, the BTA series
provides voltage insulated tab (rated at 2500 V
RMS) complying with UL standards (File ref.:
E81734).
RD91
(BTA40)
A2
A1 A2
A1 A2
G
G
TOP3 Insulated
(BTA41)
TOP3
(BTB41)
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
I T(RMS)
RMS on-state current
(full sine wave)
RD91
A
Tc = 80
°
C
TOP3
TOP3 Ins.
40
Tc = 70
C
°
I TSM
Non repetitive surge peak on-state
current (full cycle, Tj initial = 25
F = 60 Hz
t = 16.7 ms
420
A
°
C)
F = 50 Hz
t = 20 ms
400
I t
I t Value for fusing
A s
tp = 10 ms
880
Critical rate of rise of on-state current
I G =2xI GT ,tr
dI/dt
F = 120 Hz
Tj = 125
°
C
50
A/
m
s
3
100 ns
V DRM /V RRM
+ 100
Non repetitive surge peak off-state
voltage
V DSM /V RSM
tp = 10 ms
Tj = 25
°
C
V
I GM
Peak gate current
tp = 20
m
s
Tj = 125
°
C
8
A
P G(AV)
Average gate power dissipation
Tj = 125
°
C
1
W
T stg
T j
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
C
°
October 2001 - Ed: 4
1/6
787288139.002.png
BTA40 and BTA/BTB41 Series
ELECTRICAL CHARACTERISTICS (Tj = 25
°
C, unless otherwise specified)
Symbol
Test Condition s
Quadrant
Value
Unit
I GT (1)
I - II - III
IV
50
100
mA
MAX.
V D =12V
R L =33
W
V GT
ALL
MAX.
1.3
V
V GD
V D =V DRM
R L = 3.3 k
W
Tj = 125
°
C
ALL
MIN.
0.2
V
I H (2)
I T = 500 mA
MAX.
80
mA
I L
I G = 1.2 I GT
I - III - IV
MAX.
70
mA
II
160
dV/dt (2)
V D =67%V DRM gate open
Tj = 125
°
C
MIN.
500
V/
m
s
(dV/dt)c (2) (dI/dt)c = 20 A/ms
Tj = 125
°
C
MIN.
10
V/
m
s
STATIC CHARACTERISTICS
Symbol
Test Conditions
Value
Unit
V TM (2)
I TM =60A
tp=380
m
s
Tj = 25
°
C
MAX.
1.55
V
V to (2)
Threshold voltage
Tj = 125
°
C
MAX.
0.85
V
R d (2)
Dynamic resistance
Tj = 125
°
C
MAX.
10
m
W
I DRM
I RRM
V DRM =V RRM
Tj = 25
°
C
5
m
A
MAX.
Tj = 125
°
C
5
mA
Note 1: minimum IGT is guaranted at 5% of IGT max.
Note 2: for both polarities of A2 referenced to A1
THERMAL RESISTANCES
Symbol
Parameter
Value
Unit
R th(j-c)
Junction to case (AC)
RD91 (Insulated)
TOP3
°
C/W
0.9
TOP3 Insulated
1.2
R th(j-a)
Junction to ambient
TOP3
°
C/W
50
TOP3 Insulated
PRODUCT SELECTOR
Voltage (xxx)
Part Number
Sensitivity
Type
Package
600 V
800 V
BTA40-xxxB
X
X
50 mA
Standard
RD91
BTA/BTB41-xxxB
X
X
50 mA
Standard
TOP3
BTB: Non insulated TOP3 package
2/6
787288139.003.png
BTA40 and BTA/BTB41 Series
ORDERING INFORMATION
BT
A
40
-
600
B
TRIAC
SERIES
SENSITIVITY:
B: 50mA
INSULATION:
A: insulated
B: non insulated
VOLTAGE:
600: 600V
800: 800V
CURRENT:
40: 40A in RD91
41: 40A in TOP3
OTHER INFORMATION
Base
quantity
Packing
mode
Part Number
Marking
Weight
BTA40-xxxB
BTA40xxxB
20.0 g
25
Bulk
BTA/BTB41-xxxB
BTA/BTB41xxxB
4.5 g
120
Bulk
Note : xxx= voltage
Fig. 1: Maximum power dissipation versus RMS
on-state current (full cycle).
Fig.
2:
RMS
on-state
current
versus
case
temperature (full cycle).
P (W)
IT(RMS) (A)
50
45
BTA40/BTB41
40
40
35
BTA41
30
30
25
20
20
15
10
10
IT(RMS) (A)
5
Tc(
°
C)
0
0
0
5
10
15
20
25
30
35
40
0
25
50
75
100
125
3/6
787288139.004.png
BTA40 and BTA/BTB41 Series
Fig. 3: Relative variation of thermal impedance
versus pulse duration.
Fig.
4:
On-state
characteristics
(maximum
values).
ITM (A)
K=[Zth/Rth]
400
1E+0
Zth(j-c)
Tj max
100
1E-1
Zth(j-a)
BTA/BTB41
Tj=25 ° C
10
1E-2
Tj max.:
Vto = 0.85 V
Rd = 10 m W
tp (s)
VTM (V)
1E-3
1
1E-3
1E-2
1E-1
1E+0
1E+1
1E+2 5E+2
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Fig.
5:
Surge
peak
on-state
current
versus
Fig.
6:
Non-repetitive
surge
peak
on-state
number of cycles.
current
for
a
sinusoidal
pulse
with
width
tp < 10 ms, and corresponding value of I t.
ITSM (A),I t (A s)
ITSM (A)
450
3000
400
ITSM
t=20ms
350
dI/dt limitation:
50A/
One cycle
m
s
300
Non repetitive
Tj initial=25 ° C
1000
I t
250
200
150
Repetitive
Tc=70 ° C
100
50
tp (ms)
Number of cycles
Tj initial=25
°
C
0
100
1
10
100
1000
0.01
0.10
1.00
10.00
Fig. 7:
Relative variation of gate trigger current,
Fig. 8: Relative variation of critical rate of decrease
of main current versus (dV/dt)c (typical values).
holding
current
and
latching
current
versus
junction temperature (typical values).
IGT,IH,IL[Tj] / IGT,IH,IL [Tj=25
C]
°
(dI/dt)c [(dV/dt)c] / Specified (dI/dt)c
2.5
2.0
1.8
2.0
1.6
IGT
1.4
1.5
1.2
IH & IL
1.0
1.0
0.8
0.5
0.6
(dV/dt)c (V/ m s)
Tj(
°
C)
0.4
0.0
0.1
1.0
10.0
100.0
-40
-20
0
20
40
60
80
100
120
140
4/6
787288139.005.png
BTA40 and BTA/BTB41 Series
Fig.
9:
Relative
variation
of
critical
rate
of
decrease
of
main
current
versus
junction
temperature.
(dI/dt)c [Tj] / (dI/dt)c [Tj specified]
6
5
4
3
2
1
Tj ( ° C)
0
0
25
50
75
100
125
PACKAGE MECHANICAL DATA
RD91 (Plastic)
DIMENSIONS
A2
L2
L1
REF.
Millimeters
Inches
Min.
Max.
Min.
Max.
A
40.00
1.575
B2
A1
29.90
30.30
1.177
1.193
B1
C
A2
22.00
0.867
B
27.00
1.063
C2
C1
B1
13.50
16.50
0.531
0.650
A1
B2
24.00
0.945
C
14.00
0.551
C1
3.50
0.138
N2
N1
C2
1.95
3.00
0.077
0.118
E3
0.70
0.90
0.027
0.035
B
F
4.00
4.50
0.157
0.177
F
I
11.20
13.60
0.441
0.535
E3
L1
3.10
3.50
0.122
0.138
I
L2
1.70
1.90
0.067
0.075
A
N1
33
°
43
°
33
°
43
°
N2
28
°
38
°
28
°
38
°
5/6
787288139.001.png
Zgłoś jeśli naruszono regulamin