B2.pdf

(2319 KB) Pobierz
B2.pdf
SPLIT TYPE
ROOM AIR CONDITIONER
CEILING WALL type
INVERTER
Models Indoor unit Outdoor unit
RJ-14LAZ
RO-14LAZ
RJ-17LAZ
RO-17LAZ
CONTENTS
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
REFRIGERANT SYSTEM DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 3
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM . . . . . 5
OUTDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM . . . . 6
ERROR CONTENTS ......................................
9
DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . . . . . . . . . . ......
15
PARTS LIST ...........................................
18
34976601.010.png
SPECIFICATIONS
TYPE
Cooling and Heat INVERTER
INDOOR UNIT
RJ-14LAZ
RJ-17LAZ
OUTDOOR UNIT
RO-14LAZ
RO-17LAZ
COOLING CAPACITY
(kW)
: Range (kW)
4.0 (0.9 - 5.3)
4.8 (0.9 - 5.9)
HEATLING CAPACITY
(kW)
: Range
(kW)
6.0 (0.9 - 8.4)
6.7 (0.9 - 8.5)
ELECTRICAL DATA
POWER SOURCE
(V)
230
FREQUENCY
(Hz)
50
RUNNING CURRENT
Cooling
Heating
4.7
6.6
(A)
6.2
7.4
INPUT
Cooling
1.06 (0.09 - 1.75)
1.49 (0.09 - 1.90)
(kW) : Range (kW)
Heating
Cooling
Heating
1.41 (0.09 - 2.48)
1.69 (0.09 - 2.66)
E.E.R.
3.77
3.22
(kW/kW)
MOISTURE REMOVAL
4.26
3.96
2.8
( /hr)
2.1
AIR CIRCULATION-Hi
(m 3 /hr)
Cooling
Heating
840
840
970
970
COMPRESSOR
TYPE
Hermetic type, Inverter, Three phase, Induction motor, Rotary
CODE
REFRIGERANT
808 - 902 - 80
R410A (g)
1,350
FAN MOTOR
POWER SOURCE
(V)
230
HI-SPEED (r.p.m.)
1,500
INDOOR UNIT MED-SPEED (r.p.m.)
1,370
LO-SPEED (r.p.m.)
1,110
OUTDOOR UNIT
(r.p.m.)
820
850
DIMENSIONS
INDOOR UNIT HxWxD (mm)
OUTDOOR UNIT
250x890x228
578x790x300
WEIGHT
INDOOR UNIT GROSS / NET (kg)
OUTDOOR UNIT
18 / 13.5
40 / 38
REFRIGERANT CHARGE (R410A)
PIPE LENGTH
7.5 m
10 m
15 m
Additional
(ft)
(ft)
(ft)
refrigerant
FULL CHARGE AMOUNT
None
None
None
CHARGE LESS
2004.01.19
1
34976601.011.png
Performance Date
(1 / 2)
Heating
(Capacity curve)
150%
140%
130%
120%
110%
100%
IndoorDB:20
C
90%
80%
70%
60%
-10
-5
0
5
10
15
20
25
Outdoor DB( ) RH=85%
C
24
(Input curve)
180%
170%
160%
150%
140%
130%
120%
110%
100%
90%
IndoorDB:20
C
80%
-10
-5
0
2
5
10
15
20
25
Outdoor DB( ) RH=85%
C
24
(Remarks) Above measurement was conducted under the low temperature heating capacity
measuring condition, since the defrosting operation starts up at lower than 2 de
(it was measured at the compressor maximum frequency, including the defrosting
cycle.)
2003.12.24
2
34976601.012.png 34976601.013.png 34976601.001.png 34976601.002.png 34976601.003.png
Cooling
(2 / 2)
(Capacity curve)
150%
140%
130%
120%
110%
100%
Indoor:27/19
C
90%
80%
70%
60%
10
15
20
25
30
35
40
43
Outdoor DB
()
(Input curve)
120%
110%
100%
Indoor:27/19
C
90%
80%
70%
60%
50%
40%
30%
10
15
20
25
30
35
40
43
Outdoor DB
()
(Remarks) When the outdoor temperature is higher than 40 degC, the current release function
starts to operate and the copressor rotation is decreased, and the capacity goes down.
2003.12.24
3
34976601.004.png 34976601.005.png 34976601.006.png 34976601.007.png
DIMENSIONS
Models : RJ-14LAZ, RJ-17LAZ
Unit : mm
890
288
292
Models : RO-14LAZ, RO-17LAZ
508
20
540
125
790
60
300
2004.02.13
4
34976601.008.png 34976601.009.png
 
Zgłoś jeśli naruszono regulamin