Model TS715.pdf

(410 KB) Pobierz
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01//EN" "http://www.w3.org/TR/html4/strict.dtd">
TS715
single channel
timeswitch
Installation & User Instructions
868172827.051.png 868172827.062.png 868172827.073.png 868172827.075.png 868172827.001.png 868172827.002.png 868172827.003.png
Index
Installation
Product specifi cation
3
Installation
4
Wiring
5
DIL switch settings
5
Wiring Conversion
6-9
User
Your timeswitch
10
Preset programmes
10
Before you start
11
AM/PM or 24hr display
11
Setting the Time and Day
11-12
Accepting the preset programmes
12
Changing the preset programmes
13
Programming system - 5/2 day
14-15
Programming system - 7 day
16-17
Programming system - 24 hour
18
Running the programme
19
Temporary overrides
20
Changing clocks forward/back
21
Troubleshooting
22
Contact details
24
+1HR override
+1HR
MAN override
MAN
RESET
Mode
SELECT
2
868172827.004.png 868172827.005.png 868172827.006.png 868172827.007.png 868172827.008.png 868172827.009.png 868172827.010.png 868172827.011.png 868172827.012.png 868172827.013.png 868172827.014.png 868172827.015.png 868172827.016.png 868172827.017.png 868172827.018.png 868172827.019.png 868172827.020.png 868172827.021.png 868172827.022.png 868172827.023.png 868172827.024.png 868172827.025.png 868172827.026.png 868172827.027.png 868172827.028.png 868172827.029.png 868172827.030.png 868172827.031.png 868172827.032.png 868172827.033.png 868172827.034.png 868172827.035.png 868172827.036.png 868172827.037.png 868172827.038.png 868172827.039.png 868172827.040.png 868172827.041.png 868172827.042.png 868172827.043.png 868172827.044.png 868172827.045.png 868172827.046.png 868172827.047.png 868172827.048.png 868172827.049.png 868172827.050.png 868172827.052.png 868172827.053.png 868172827.054.png
Installation Instructions
Please Note:
This product should only be installed by a
qualifi ed electrician or competent heating installer,
and should be in accordance with the current
edition of the IEEE wiring regulations.
Product specifi cation
Specifi cation
Power supply
230 Vac, ±15%, 50/60 Hz
Switching action
1 x SPDT voltage free, Type 1B
Switch rating
Max 264 Vac, 3(1)A
Battery back-up
24 hours minimum
Setting/Running Accuracy
±1 minute
Dimensions, mm (W, H, D)
135 x 88 x 32
Design standard
EN 60730-2-7
Control Pollution Situation
Degree 2
Rated Impulse Voltage
2.5kV
Ball Pressure Test
75°C
3
868172827.055.png 868172827.056.png 868172827.057.png
Installation
Remove wallplate from unit by unscrewing the two
screws on the bottom edge of the unit.
From the top left hand corner of the wallplate, there
must be clearances of at least 140 mm to the right,
15mm to the left, 30mm above and 100mm below in
order to mount the plug-on module.
The wallplate must be securely mounted either
directly to the wall using suitable wood screws or to a
fl ush mounted 1-gang electrical accessory box using
M3.5 screws.
Cable access can either be from behind for
concealed cabling, or from below for surface cabling.
If surface cable is used, cut out cable access slot on
plug-on module prior to mounting the module.
For wiring connections refer to diagram on page 5.
TS715 models are double insulated and do not
require an earth connection, however a parking
terminal is provided on the wallplate. This is clearly
marked with an Earth symbol.
Prior to mounting the plug-on module, DIL switches
on the rear of the plug-on module must be set. See
diagram on page 5 for available options.
Mount plug-on module to wallplate by locating tabs
on top of wallplate in apertures on rear of module,
hinge down and press fi rmly to wallplate before
tightening securing screws on bottom of wallplate.
4
868172827.058.png
Wiring
NOTE:
Link terminals
L and 1 for
standard mains
voltage operated
systems
Mains
fused
3A
COM
OFF
ON
Always switch off mains fi rst and never fi t
programmer to a live wallplate.
For Wiring Conversion tables see pages 6-9
DIL Switch Settings
Before mounting the unit, ensure
the 4 DIL switches on the rear of
the unit have been moved to the
required settings
!
Remember to tick the
INSTALLER SETTING box on
the inside fl ap label to notify
user in which
mode their unit
is set (24hr, 5/2
day or 7 day).
INSTALLER SETTING
24 Hour
5+2 Day
7 Day
5
868172827.059.png 868172827.060.png 868172827.061.png 868172827.063.png 868172827.064.png 868172827.065.png 868172827.066.png 868172827.067.png 868172827.068.png 868172827.069.png 868172827.070.png 868172827.071.png 868172827.072.png 868172827.074.png
 
Zgłoś jeśli naruszono regulamin