MODSLA_E.PDF
(
653 KB
)
Pobierz
Modbus Slave Hdb.
SIMATIC
Loadable Driver CP 441-2
MODBUS Protocol, S7 is Slave
Manual
Preface,
Contents
Product Description
1
SIMATIC
Installation
2
3
Mode of Operation
Loadable Driver for Point-to-Point CPs
MODBUS Protocol
RTU Format
S7 is Slave
Commissioning the Driver
4
Commissioning the FB
5
CPU - CP Interface
6
Manual
Transmission Protocol
7
Function Codes
8
Diagnostics of the Driver
9
Diagnostics of the FB
10
Appendices
Technical Data
A
Literature List
B
Glossary,
Index
Edition 2
Safety Guidelines
This manual contains notices which you should observe to ensure your own personal
safety, as well as to prevent damage to property. These notices are highlighted in the
manual by a warning triangle and are marked as follows according to the level of danger:
__________________________________________________________________
Danger
!
indicates that death, severe personal injury, or substantial property damage
will
result if
proper precautions are not taken.
__________________________________________________________________
__________________________________________________________________
Warning
!
indicates that death, severe personal injury, or substantial damage
can
result if proper
precautions are not taken.
__________________________________________________________________
__________________________________________________________________
Caution
!
indicates that minor personal injury or property damage can result if proper precautions are
not taken.
__________________________________________________________________
__________________________________________________________________
Note
draws your attention to particularly important information on the product, handling the
product, or to a particular part of the documentation.
__________________________________________________________________
Qualified Personnel
Only
qualified personnel
should be allowed to commission and operate the equipment.
Qualified persons are defined as persons who are authorized to commission, to ground,
and to tag circuits, equipment, and systems in accordance with established safety
practices and standards.
Correct Usage
Note the following:
________________________________________________________________________
!
Warning
This device may only be used for the applications described in the catalog and the
technical description and only in connection with devices or components from other
manufacturers which have been approved or recommended by Siemens.
This product can only function correctly and safely if it is transported, stored, set up, and
installed correctly, and operated and maintained as recommended.
Trademarks
SIMATIC
â
and SINEC
â
are registered trademarks of SIEMENS AG.
Third parties using for their own purposes any other names in this manual which refer to
trademarks might infringe upon the rights of the trademark owners.
Copyright
ã
Siemens AG 1998 All Rights Reserved
Disclaimer of Liability
The reproduction, transmission, or use of this document or its contents is
not permitted without express written authority. Offenders will be liable for
damages. All rights reserved, including rights created by patent grant or
registration of a utility model or design, are reserved.
We have checked the contents of this manual for agreement with the
hardware and software described. Since deviations cannot be precluded
entirely, we cannot guarantee full agreement. However, the data in this
manual are reviewed regularly and any necessary corrections included in
subsequent editions. Suggestions for improvement are welcomed.
ã
Siemens AG 1998
Subject to change without prior notice.
Preface
Preface
Purpose of this
Manual
The information in this manual will enable you to establish and commission
a data link between a CP in the form of a “Modbus capable” slave and a
Modbus Master control system.
Contents of the
Manual
This manual describes the function of the loadable driver and how it is
linked to the hardware and software of the CP 341 and CP 441-2
communications processors.
The manual covers the following topics:
·
Product Description / Installation
·
Mode of Operation of the Data Link
·
Commissioning the Driver / Installation / Parameter Assignment
·
Commissioning the Function Block / Parameter Assignment / STEP 7
Application Example
·
CPU-CP Interface
·
Transmission Protocol / Function Codes
·
Diagnostics of the Function Block
Validity of the
Manual
This manual is valid for the following software package:
Product
Order Number
from Version
Loadable Driver for Point-to-
Point CPs
6ES7 870-1AB00-0YA0 2.0
Note
This manual contains the description of the driver and the function block as
is valid at the time of publication.
How to Access the
Information in this
Manual
To enable you to access the information in this manual more easily, we
would like to draw your attention to the following:
·
The next few pages contain a complete list of contents.
Further Sources of
Information
Any further information (installation, commissioning, etc.) can be found in
the manual for the CP used.
Loadable Driver for Point-to-Point CPs: MODBUS Protocol, S7 is Slave
6ES7 870-1AB00-0YA0, Manual Edition 2
iii
Diagnostics of the Driver
·
Plik z chomika:
masterkom
Inne pliki z tego folderu:
ET200iS_e.pdf
(22821 KB)
DOC_AS_PL_S7300_HW_moduly.pdf
(7881 KB)
DPPA_E.PDF
(4575 KB)
dyn_funktion_e.pdf
(4571 KB)
Cpu210_e.pdf
(1429 KB)
Inne foldery tego chomika:
Autoryzacja
Kable
Logo
OP Panels
S5
Zgłoś jeśli