MC45 AT Command Set.pdf
(
2804 KB
)
Pobierz
Microsoft Word - mc45_at_commands.doc
MC45 / MC46
Siemens Cellular Engine
Version: 03.05
DocID:
MC45 / MC46_ATC_V03.05
MC45 / MC46 AT Command Set
Confidential / Released
s
m
o
b
i
l
e
Document Name:
MC45 / MC46 AT Command Set
Version:
03.05
Date:
November 10, 2003
DocId:
MC45 / MC46_ATC_V
03.05
Status:
Confidential / Released
General Notes
Product is deemed accepted by recipient and is provided without interface to recipientÓs products. The
documentation and/or product are provided for testing, evaluation, integration and information pur-
poses. The documentation and/or product are provided on an Ðas isÑ basis only and may contain defi-
ciencies or inadequacies. The documentation and/or product are provided without warranty of any
kind, express or implied. To the maximum extent permitted by applicable law, Siemens further dis-
claims all warranties, including without limitation any implied warranties of merchantability, complete-
ness, fitness for a particular purpose and non-infringement of third-party rights. The entire risk arising
out of the use or performance of the product and documentation remains with recipient. This product is
not intended for use in life support appliances, devices or systems where a malfunction of the product
can reasonably be expected to result in personal injury. Applications incorporating the described prod-
uct must be designed to be in accordance with the technical specifications provided in these guide-
lines. Failure to comply with any of the required procedures can result in malfunctions or serious dis-
crepancies in results. Furthermore, all safety instructions regarding the use of mobile technical sys-
tems, including GSM products, which also apply to cellular phones must be followed. Siemens or its
suppliers shall, regardless of any legal theory upon which the claim is based, not be liable for any con-
sequential, incidental, direct, indirect, punitive or other damages whatsoever (including, without limita-
tion, damages for loss of business profits, business interruption, loss of business information or data,
or other pecuniary loss) arising out the use of or inability to use the documentation and/or product,
even if Siemens has been advised of the possibility of such damages. The foregoing limitations of li-
ability shall not apply in case of mandatory liability, e.g. under the German Product Liability Act, in
case of intent, gross negligence, injury of life, body or health, or breach of a condition which goes to
the root of the contract. However, claims for damages arising from a breach of a condition, which goes
to the root of the contract, shall be limited to the foreseeable damage, which is intrinsic to the contract,
unless caused by intent or gross negligence or based on liability for injury of life, body or health. The
above provision does not imply a change on the burden of proof to the detriment of the recipient. Sub-
ject to change without notice at any time. The interpretation of this general note shall be governed and
construed according to German law without reference to any other substantive law.
Copyright
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its
contents and communication thereof to others without express authorization are prohibited. Offenders
will be held liable for payment of damages. All rights created by patent grant or registration of a utility
model or design patent are reserved.
Copyright ¨ Siemens AG 2003
MC45 / MC46_ATC_V03.05
Page 2 of 345
10.11.2003
MC45 / MC46 AT Command Set
Confidential / Released
s
Contents
0
Document History .........................................................................................9
1
Introduction .................................................................................................17
1.1
Scope of the document ...........................................................................................................17
1.2
Related documents .................................................................................................................17
1.3
Conventions and abbreviations...............................................................................................18
1.4
AT command syntax ...............................................................................................................18
1.4.1
Using parameters....................................................................................................................18
1.4.2
Combining AT commands on the same command line ..........................................................19
1.4.3
Entering successive AT commands on separate lines ...........................................................19
1.4.4
Communication between customer application and MC45 / MC46 ........................................19
1.4.5
Unsolicited Result Codes (URCs)...........................................................................................20
1.5
Supported character sets ........................................................................................................21
1.5.1
UCS2 and GSM data coding and conversion in SMS text mode and Remote-SAT...............22
1.6
Flow control .............................................................................................................................25
1.6.1
Software flow control (XON/OFF flow control) ........................................................................25
1.6.2
Hardware flow control (RTS/CTS flow control) .......................................................................25
1.7
Common PCN Handset Specification (CPHS.........................................................................26
2
Standard V.25ter AT Commands ...............................................................27
2.1
A/ Repeat previous command line .........................................................................................27
2.2
+++ Switch from data mode or PPP online mode to command mode...................................27
2.3
AT\Qn Flow control ................................................................................................................28
2.4
ATA Answer a call..................................................................................................................29
2.5
ATD Mobile originated call to dial a number ..........................................................................30
2.6
ATD><mem><n> Originate call to phone number <n> in memory <mem> ..........................32
2.7
ATD><n> Originate call to phone number selected from active memory ..............................34
2.8
ATD><str> Originate call to phone number in memory with corresponding field ..................35
2.9
ATDI Mobile originated call to dialable ISDN number <n> ....................................................36
2.10
ATDL Redial last telephone number used .............................................................................37
2.11
ATE Enable command echo ..................................................................................................38
2.12
ATH Disconnect existing connection .....................................................................................38
2.13
ATI Display product identification information........................................................................39
2.14
ATI[value] Display additional identification information..........................................................39
2.15
ATL Set monitor speaker loudness........................................................................................40
2.16
ATM Set monitor speaker mode ............................................................................................40
2.17
ATO Switch from command mode to data mode / PPP online mode ....................................40
2.18
ATQ Set result code presentation mode................................................................................41
2.19
ATP Select pulse dialing ........................................................................................................41
2.20
ATS0 Set number of rings before automatically answering the call ......................................42
2.21
ATS3 Write command line termination character ..................................................................43
2.22
ATS4 Set response formatting character...............................................................................43
2.23
ATS5 Write command line editing character..........................................................................43
2.24
ATS6 Set pause before blind dialing......................................................................................44
2.25
ATS7 Set number of seconds to wait for connection completion ..........................................44
2.26
ATS8 Set number of seconds to wait for comma dial modifier ..............................................45
2.27
ATS10 Set disconnect delay after indicating the absence of data carrier .............................45
2.28
ATS18 Extended error report .................................................................................................46
2.29
ATT Select tone dialing ..........................................................................................................47
2.30
ATV Set result code format mode..........................................................................................47
2.31
ATX Set CONNECT result code format and call monitoring..................................................47
2.32
ATZ Set all current parameters to user defined profile ..........................................................48
2.33
AT&C Set circuit Data Carrier Detect (DCD) function mode..................................................48
MC45 / MC46_ATC_V03.05
Page 3 of 345
10.11.2003
m
o
b
i
l
e
MC45 / MC46 AT Command Set
Confidential / Released
s
2.34
AT&D Set circuit Data Terminal Ready (DTR) function mode ...............................................49
2.35
AT&F Set all current parameters to manufacturer defaults ...................................................50
2.36
AT&S Set circuit Data Set Ready (DSR) function mode........................................................52
2.37
AT&V Display current configuration .......................................................................................53
2.38
AT&W Store current configuration to user defined profile .....................................................55
2.39
AT+GCAP Request complete TA capabilities list ..................................................................57
2.40
AT+GMI Request manufacturer identification........................................................................57
2.41
AT+GMM Request TA model identification............................................................................57
2.42
AT+GMR Request TA revision identification of software status ............................................58
2.43
AT+GSN Request TA serial number identification (IMEI)......................................................58
2.44
AT+ILRR Set TE-TA local rate reporting ................................................................................59
2.45
AT+IPR Set fixed local rate.....................................................................................................60
2.45.1
Autobauding ............................................................................................................................61
3
AT Commands for FAX...............................................................................62
3.1
AT+FBADLIN Bad Line Threshold .........................................................................................63
3.2
AT+FBADMUL Error Threshold Multiplier..............................................................................63
3.3
AT+FBOR Query data bit order .............................................................................................64
3.4
AT+FCIG Query or set the Local polling id ............................................................................65
3.5
AT+FCLASS Fax: Select, read or test service class .............................................................66
3.6
AT+FCQ Copy Quality Checking ...........................................................................................67
3.7
AT+FCR Capability to receive................................................................................................67
3.8
AT+FDCC Query or set capabilities.......................................................................................68
3.9
AT+FDFFC Data Compression Format Conversion ..............................................................69
3.10
AT+FDIS Query or set session parameters...........................................................................70
3.11
AT+FDR Begin or continue phase C data reception..............................................................71
3.12
AT+FDT Data Transmission ..................................................................................................71
3.13
AT+FET End a page or document .........................................................................................72
3.14
AT+FK Kill operation, orderly FAX abort................................................................................72
3.15
AT+FLID Query or set the Local Id setting capabilities .........................................................72
3.16
AT+FMDL Identify Product Model..........................................................................................73
3.17
AT+FMFR Request Manufacturer Identification ....................................................................73
3.18
AT+FOPT Set bit order independently...................................................................................73
3.19
AT+FPHCTO DTE Phase C Response Timeout ...................................................................74
3.20
AT+FREV Identify Product Revision ......................................................................................74
3.21
AT+FRH Receive Data Using HDLC Framing .......................................................................74
3.22
AT+FRM Receive Data ..........................................................................................................75
3.23
AT+FRS Receive Silence ......................................................................................................75
3.24
AT+FTH Transmit Data Using HDLC Framing ......................................................................75
3.25
AT+FTM Transmit Data .........................................................................................................76
3.26
AT+FTS Stop Transmission and Wait ...................................................................................76
3.27
AT+FVRFC Vertical resolution format conversion .................................................................77
4
AT Commands originating from GSM 07.07 .............................................78
4.1
AT+CACM Accumulated call meter (ACM) reset or query ....................................................78
4.2
AT+CALA Set alarm time.......................................................................................................79
4.3
AT+CAMM Accumulated call meter maximum (ACMmax) set or query................................82
4.4
AT+CAOC Advice of Charge information ..............................................................................83
4.5
AT+CBST Select bearer service type ....................................................................................84
4.6
AT+CCFC Call forwarding number and conditions control....................................................85
4.6.1
Examples: Call forwarding ......................................................................................................87
4.7
AT+CCLK Real Time Clock ...................................................................................................88
4.8
AT+CCUG: Closed User Group ..............................................................................................89
4.9
AT+CCWA Call waiting ..........................................................................................................90
4.10
AT+CEER Extended error report ...........................................................................................93
4.11
AT+CFUN Set phone functionality .........................................................................................95
4.11.1
Wake up the ME from SLEEP mode.......................................................................................98
4.12
AT+CGMI Request manufacturer identification ......................................................................99
MC45 / MC46_ATC_V03.05
Page 4 of 345
10.11.2003
m
o
b
i
l
e
MC45 / MC46 AT Command Set
Confidential / Released
s
4.13
AT+CGMM Request model identification...............................................................................99
4.14
AT+CGMR Request revision identification of software status ...............................................99
4.15
AT+CGSN Request product serial number identification (IMEI) identical to GSN ..............100
4.16
AT+CHLD Call hold and multiparty .......................................................................................101
4.17
AT+CHUP Hang up call .......................................................................................................104
4.18
AT+CIMI Request international mobile subscriber identity..................................................104
4.19
AT+CIND Indicator control ....................................................................................................105
4.20
AT+CLCC List current calls of ME .......................................................................................108
4.21
AT+CLCK Facility lock .........................................................................................................110
4.21.1
Examples: Enabling / disabling PIN 1 authentication ...........................................................113
4.21.2
Examples: Phone lock...........................................................................................................114
4.21.3
Examples: Call barring ..........................................................................................................116
4.22
AT+CLIP Calling line identification presentation..................................................................117
4.23
AT+CLIR Calling line identification restriction (by *# sequence) .........................................118
4.24
AT+CLVL Loudspeaker volume level ..................................................................................119
4.25
AT+CMEE Report mobile equipment error ..........................................................................120
4.26
AT+CMER Mobile equipment event reporting .....................................................................121
4.27
AT+CMUT Mute control .......................................................................................................123
4.28
AT+CMUX Enter multiplex mode .........................................................................................124
4.28.1
Restricted use of AT commands in Multiplex mode..............................................................125
4.28.2
Second serial interface ASC1 ...............................................................................................127
4.29
AT+COPN Read operator names ........................................................................................128
4.30
AT+COPS Operator selection..............................................................................................129
4.31
AT+CPAS Mobile equipment activity status ........................................................................132
4.32
AT+CPBR Read current phone book entries.......................................................................133
4.33
AT+CPBS Select phone book memory storage...................................................................135
4.34
AT+CPBW Write phone book entry .....................................................................................137
4.35
AT+CPIN Enter PIN .............................................................................................................140
4.35.1
What to do if PIN or password authentication fails? .............................................................143
4.36
AT+CPIN2
Enter PIN2 .........................................................................................................145
4.38
AT+CPWD Change password .............................................................................................148
4.39
AT+CR Service reporting control .........................................................................................151
4.40
AT+CRC Set Cellular Result Codes for incoming call indication.........................................152
4.41
AT+CREG Network registration ...........................................................................................153
4.42
AT+CRLP Select radio link protocol param. for orig. non-transparent data call ..................156
4.43
AT+CRSM Restricted SIM access .......................................................................................157
4.44
AT+CSCS Select TE character set ......................................................................................158
4.45
AT+CSNS Single Numbering Scheme ................................................................................159
4.46
AT+CSQ Signal quality ........................................................................................................160
4.47
AT+CSSN Supplementary service notifications...................................................................161
4.48
AT+CUSD Unstructured supplementary service data .........................................................162
4.49
AT+VTD=<n> Tone duration................................................................................................163
4.50
AT+VTS DTMF and tone generation (<Tone> in {0-9, *, #, A, B, C, D}) .............................164
4.51
AT+WS46 Select wireless network .......................................................................................165
5
AT commands originating from GSM 07.05 for SMS .............................166
5.1
AT+CMGC Send an SMS command ...................................................................................166
5.2
AT+CMGD Delete SMS message........................................................................................167
5.3
AT+CMGF Select SMS message format .............................................................................167
5.4
AT+CMGL List SMS messages from preferred store ..........................................................168
5.5
AT+CMGR Read SMS message .........................................................................................171
5.6
AT+CMGS Send SMS message..........................................................................................174
5.7
AT+CMGW Write SMS message to memory.......................................................................176
5.8
AT+CMSS Send SMS message from storage.....................................................................178
5.9
AT+CNMA New SMS message acknowledge to ME/TE, only phase 2+ ............................179
5.10
AT+CNMI New SMS message indications ..........................................................................180
5.11
AT+CPMS Preferred SMS message storage ......................................................................183
5.12
AT+CSCA SMS service centre address ..............................................................................185
MC45 / MC46_ATC_V03.05
Page 5 of 345
10.11.2003
m
o
b
i
l
e
4.37
AT+CPUC
Price per unit and currency table .......................................................................146
Plik z chomika:
masterkom
Inne pliki z tego folderu:
Symulator S7 200.rar
(827 KB)
S7 Unlock(1).rar
(10713 KB)
S7 Card.rar
(428 KB)
S7 Unlock.rar
(776 KB)
S7 Image rider & writer.rar
(428 KB)
Inne foldery tego chomika:
Autoryzacja
Kable
Logo
Manual
OP Panels
Zgłoś jeśli
naruszono regulamin