ICs for Consumer Electronics
DDC-PLUS-Deflection Controller
SDA 9362
Data Sheet 1998-02-01
Edition 1998-02-01
This edition was realized using
the software system FrameMaker
â
Published by Siemens AG, Bereich
Halbleiter, Marketing-Kommunikation,
Balanstraße 73,
81541 München
©
Siemens AG 1998.
All Rights Reserved.
Attention please!
As far as patents or other rights of third
parties are concerned, liability is only
assumed for components, not for
applications, processes and circuits
implemented within components or
assemblies.
The information describes the type of
component and shall not be considered
as assured characteristics.
Terms of delivery and rights to change
design reserved.
For questions on technology, delivery
and prices please contact
the Semiconductor Group Offices in
Germany or the Siemens Companies and
Representatives worldwide
(see address list).
Due to technical requirements compo-
nents may contain dangerous substanc-
es. For information on the types in ques-
tion please contact your nearest
Siemens Office, Semiconductor Group.
Siemens AG is an approved CECC man-
ufacturer.
Packing
Please use the recycling operators
known to you. We can also help you – get
in touch with your nearest sales office. By
agreement we will take packing material
back, if it is sorted. You must bear the
costs of transport.
For packing material that is returned to us
unsorted or which we are not obliged to
accept, we shall have to invoice you for
any costs incurred.
Components used in life-support de-
vices or systems must be expressly
authorized for such purpose!
Critical components
1
of the Semiconduc-
tor Group of Siemens AG, may only be
used in life-support devices or systems
2
with the express written approval of the
Semiconductor Group of Siemens AG.
1 A critical component is a component
used in a life-support device or system
whose failure can reasonably be
expected to cause the failure of that
life-support device or system, or to
affect its safety or effectiveness of that
device or system.
2 Life support devices or systems are
intended (a) to be implanted in the
human body, or (b) to support and/or
maintain and sustain human life. If
they fail, it is reasonable to assume
that the health of the user may be
endangered.
SDA 9362
Revision History:
Current Version: 1998-02-01
Previous Version:
1997-04-01
Page
(in previous
Version)
Page
(in current
Version)
Subjects (major changes since last revision)
30
32
Nom./max. average current and max. standby current specified
30
32
Specification of charge current pump of PLL pin LF is unnecessary
Data Classification
Maximum Ratings
Maximum ratings are absolute ratings; exceeding only one of these values may cause
irreversible damage to the integrated circuit.
Recommended Operating Conditions
Under this conditions the functions given in the circuit description are fulfilled. Nominal
conditions specify mean values expected over the
production
spread and are the
proposed values for interface and application. If not stated otherwise, nominal values will
apply at
T
A
=25°C and the
nominal supply voltage.
Characteristics
The listed characteristics are ensured over the operating range of the integrated circuit.
Edition 1998-02-01
Published by Siemens AG, Semiconductor Group
Copyright
ã
Siemens AG 1998. All rights reserved.
Terms of delivery and right to change design reserved.
SDA 9362
Table of Contents
Page
1
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3
Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4
Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 System Description
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2 Circuit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.3 Reset Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.4 Frequency Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5 I²C-Bus Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.5.1 I²C-Bus Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.5.2 I²C-Bus Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.5.3 I²C-Bus Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.5.4 Detailed Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.5.5 Explanation of Some Control Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3
Absolute Maximum Ratings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.1
Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
3.2
Characteristics (Assuming Recommended Operating Conditions) . . . . . . . 32
4
Application Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5
Waveforms
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.1
VD- Output Voltage, 4/3-CRT and 16/9-Source . . . . . . . . . . . . . . . . . . . . . . 35
5.2
Function of H,V Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.3
Power On/Off Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.4
Standby Mode, RESN Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6
Package Outlines
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Semiconductor Group
4
1998-02-01
DDC-PLUS-Deflection Controller
SDA 9362
MOS
1
Overview
1.1 Features
• Deflection - Protection - 16:9 / 4:3
•
I
F
2)
• PW EHT compensation
• PH EHT compensation
• Compensation of H-phase deviation
(e.g. caused by white bar)
• Upper/lower EW-corner correction separately adjustable
• V-angle correction: Vertical frequent linear modulation of H-phase
• V-bow correction: Vertical frequent parabolic modulation of H-phase
• Three reduced V-scan modes (75 %, 66 %, 50 % V-size) selectable
• H- and V-blanking time adjustable
• Partial overscan adjustable to hide the cut off control measuring lines in the reduced
scan modes
• Stop/start of vertical deflection adjustable to fill out the 16/9 screen with different
letterbox formats without annoying overscan
• Dynamic PH EHT-compensation (white bar)
• Self adaptation of V-frequency/number of lines per field between 192 and 680 for each
possible line frequency
• Protection against EHT run away (X-rays protection)
• Protection against missing V-deflection (CRT-protection)
• Two digital outputs for general purpose, controlled by
P-MQFP-44-2
I
2
C Bus
• Selectable softstart of the H-output stage
• P-MQFP-44-2 package
• 5 V supply voltage
Type
Ordering Code
Package
SDA 9362
Q67101-H5173-A701
P-MQFP-44-2
Semiconductor Group
5
1998-02-01
2
C Bus alignment of all deflection parameters
• All EW-, V- and H-functions (incl.
Plik z chomika:
jj63
Inne pliki z tego folderu:
1.5kexx.pdf
(57 KB)
10riaxxx.pdf
(521 KB)
12fl60xx.pdf
(304 KB)
150k60a.pdf
(83 KB)
163306.pdf
(32 KB)
Inne foldery tego chomika:
Pliki dostępne do 01.06.2025
1976 - Bitwa o Midway
1980
Dokumenty
Dokumenty(1)
Zgłoś jeśli
naruszono regulamin